Most difficulties in working with Micro-Manager arise from configuring the system and from problems/issues with specific devices. In both of these cases you are interacting mainly with device adapters. These device adapters have been written by several different authors, all behave slightly differently, and interact with specific hardware that has its own peculiarities. On these pages we will maintain as much information as possible about Micro-Manager device adapters. This will help you configure and understand your Micro-Manager system. We hope that the authors of the device adapters will maintain this information, but please feel free to update the information here with your own experiences. The information here will refer to the most recent Micro-Manager release.

Motorized Microscopes

  • LeicaDMI - Leica DMI and DM microscopes
  • LeicaDMR - Leica DMR microscopes (and DMIRBE)
  • MoticMicroscope - Motic BA600 microscopes
  • NikonAZ100 - Nikon AZ100 Zoom microscope
  • NikonEclipse90i - Nikon Eclipse 90i motorized microscope
  • NikonTE2000 - Nikon TE2000 motorized microscope
  • NikonTI - Nikon Ti microscope
  • NikonTi2 - Nikon Ti2 microscope
  • Olympus - Olympus IX81 (Inverted)/BX61 (Upright)
  • OlympusIX83 - Olympus IX83 motorized microscope
  • ZeissCAN - Zeiss CAN-bus (not CAN29) compatible microscopes (Axiovert 200m, Axioplan2)
  • ZeissCAN29 - Zeiss CAN29-bus compatible microscopes (AxioObserver)
  • ZeissAxioZoom - Zeiss AxioZoom microscope (CAN29)

Cameras

Select and hold (or right-click) the device and select Update driver software. From the context menu. In the wizard, select Browse my computer for driver software. Select Let me pick from a list of device drivers on my computer. From the list of device classes, select Universal Serial Bus devices. The wizard displays WinUsb Device. Select it to load the driver. 1 COS 318: Operating Systems I/O Device and Drivers 2 Input and Output A computer’s job is to process data Computation (CPU, cache, and memory) Move data into and out of a system (between I/O devices and memory) Challenges with I/O devices Different categories: storage, networking, displays, etc. Large number of device drivers to support. 3 9 Programmed I/O u uExample l A polling loop RS-232 serial port u Simple serial controller l Status registers (ready, busy, l I/O Bus Data register u Output CPU: l controller Wait until device is not “busy” l Write data to “data” register l Tell device “ready” Device l lWait until “ready” l Clear “ready” and set “busy”.

  • ABSCamera - Cameras from ABS Gesellschaft für Automatisierung, Bildverarbeitung, Software GmbH Jena
  • AmScope - AmScope MU series cameras (Windows)
  • Andor - Andor cameras (CCD and EMCCD)
  • AndorSDK3 - New model Andor cameras (sCMOS)
  • Apogee - Apogee cameras
  • AxioCam - Zeiss AxioCam medium resolution and high resolution models (Windows)
  • BaslerAce - Basler Ace USB Cameras
  • BaslerCameras - All Basler cameras that are supported by pylon SDK
  • BaumerOptronic - Leica DFC camera (through BaumerOptronic FXLib)
  • BiostepEagleIce - biostep EagleIce camera
  • dc1394 - Firewire cameras that adhere to the iidc1394 specs (see also IIDC)
  • DECamera - Direct Electron Cameras
  • DemoCamera - Virtual, emulated equipment for testing
  • Dhyana - Dhyana/Tucsen cameras
  • DSLRRemoteCamera - Canon DSLR cameras (Windows)
  • FakeCamera - Virtual camera that loads images from disk (Windows, Linux)
  • FirstLightImagingCamera - First Light Imaging Cameras
  • FLICamera - Finger Lakes Instrumentation Cameras
  • GigECamera - GigE Vision- and GenICam-compliant cameras
  • GPhoto - Canon and Nikon DSLR cameras (Mac, Linux)
  • Hamamatsu - Legacy adapter for Hamamatsu cameras (via DCAM-API); now Mac only
  • HamamatsuHam - Hamamatsu cameras (via DCAM-API)
  • IDS_uEye - IDS uEye USB cameras (also Thorlabs DCUxxxx, Edmund EO-xxxxM) (Linux, Windows)
  • IIDC - Firewire (and USB) cameras compatible with the IIDC specification (see also dc1394)
  • JAI - JAI Cameras (eBUS)
  • Leica Cameras - These use the BaumerOptronic adapter
  • Lumenera - Lumenera cameras
  • MATRIX VISION devices - MATRIX VISION GmbH USB3 Vision, GigE Vision and USB2 cameras as well as various frame grabber boards
  • Micropix - Cameras from Micropix
  • Mightex_C_Cam - Mightex C-series USB cameras
  • MoticCamera - Motic cameras
  • NKRemoteCamera - Nikon Digital SLR (Windows)
  • OpenCVgrabber - Supports numerous USB cameras and frame grabbers (those using a DirectShow or WDM class driver). (Windows)
  • PCO_Camera - Supports all pco.sdk based cameras (pco.edge, pco.panda and others)
  • Photometrics - A.k.a. PVCAM
  • PICAM - Princeton Instruments cameras using the PICam interface
  • Piper - Stanford Photonics cameras
  • Pixelink - Pixelink Cameras
  • Point Grey Research - Point Grey (now FLIR) cameras through the Flycap2 interface, also see Spinnaker
  • PrincetonInstruments - Princeton Instruments cameras
  • ProgRes - Jenoptik cameras (ProgRes series)
  • PSRemoteCamera - Canon PowerShot camera (Windows)
  • PVCAM - Roper/Photometrics cameras (not for Princeton Instruments)
  • QCam - QImaging cameras
  • QSICamera - QSI cameras (Windows)
  • RaptorEPIX - Raptor Photonics cameras using EPIX cameralink board
  • ScionCam - Scion cameras
  • Sensicam - PCO/Cooke Sensicam camera
  • SigmaKoki - Sigma Koki camera
  • Spinnaker - FLIR (formally Point Grey) cameras though the Spinnaker interface
  • SpotCamera - Diagnostic Instruments Spot cameras
  • TetheredCam - Canon and Nikon DSLR cameras (Windows)
  • ThorlabsUSBCamera - Thorlabs cameras (Windows)
  • TIScam - The Imaging Source cameras (tested on USB/CCD models) and video frame grabbers
  • TSI - Thorlabs Scientific Imaging Cameras
  • TwainCamera - Cameras fully implementing Twain Imaging Standard
  • Veroptics - Veroptics cameras
  • Video4Linux - Video4Linux compatible cameras
  • XIMEACamera - XIMEA cameras (and some Olympus Soft Imaging cameras)


Stages, filter wheels, shutters

  • ArduinoNeoPixel - Adafruit NeoPixel RGB LEDs controlled through an Arduino
  • ASIFW1000 - ASI Shutter and Filter Wheel controller
  • ASIStage - ASI XY (and Z) stage and CRIF
  • ASITiger - ASI TG-1000 'Tiger' Controller (hub device, peripherals include multiple stage types, filter wheel, shutters, micro-mirrors, etc.)
  • ChuoSeiki_MD5000 - ChuoSeiki MD5000 series controller: 2-axis, single axis
  • ChuoSeiki_QT - ChuoSeiki QT series controller: 3-axis, 2-axis, single axis
  • CoolLED - LED illuminator (usable as a shutter device)
  • CONEX - See NewportCONEX
  • Conix - Conix Filter Changer, XY and Z stage
  • Corvus - Märzhäuser XY stages with Corvus driver.
  • DA-Z-Stage - For stages that can be controlled with analogue voltage. Needs a DA device
  • DAShutter - Treats a DA output as a shutter. Useful (for instance) for diode lasers
  • IntelLiDrive - IntelLiDrive stages are support through 3d party adapters
  • KDV - kdvelectronics focus drive (z-stage) for Meiji Techno
  • LeicaDMSTC - Leica DMSTC XY stage
  • LMT200-V3 - ITK Dr. Kassen LMT200-V3 HYDRA Controller and XY stage
  • Ludl - Ludl stages, shutters and filter wheels
  • LudlLow - Ludl stages, shutters and filter wheels (other)
  • Marzhauser - Märzhäuser XY stages and Z (uses TANGO controller)
  • MarzhauserLStep - Märzhäuser LStep stage controller
  • MarzhauserLStepOld - Old version (1.2) of Märzhäuser LStep stage controller
  • MCL_MicroDrive - Mad City Labs MicroDrive
  • MCL_NanoDrive - Mad City Labs NanoDrive
  • MT20 - Olympus MT20 illumination source (Lamp/shutter/filter wheel)
  • MP285 - Sutter Micro-Manipulator
  • NewportCONEX - Newport CONEX-CC servo controller
  • NewportSMC - Newport SMC100 single-axis motor controller
  • Nikon - Nikon Z-drive, TIRF shutter and IntensiLight shutter
  • NIMotionStage - National Instruments FlexMotion stage controls
  • NPointC400 - nPoint C.400 and LC.400 axis controllers
  • ObjectiveImaging - Objective Imaging OASIS controller
  • PI_GCS_2 - Physik Instrumente (PI) GCS2 adapter
  • PI_GCS - Physik Instrumente (PI) GCS adapter - Z Stage connected to PI GCS controller (E-665, E-621, E-625, E-753, ...)
  • PI - Other (older) Physik Instrumente devices. Includes the E-662 controller
  • PicardStage - Picard Industries USB Slide I/II and USB Twister
  • PIEZOCONCEPT - PIEZOCONCEPT nanopositioners
  • Piezosystem_30DV50 - Piezosystem Jena. digital one channel controller
  • Piezosystem_dDrive - Piezosystem Jena. digital 6 channel controller with display
  • Piezosystem_NV40_1 - Piezosystem Jena. one channel controller for older stages
  • Piezosystem_NV40_3 - Piezosystem Jena. 3 channel controller with USB
  • Piezosystem_NV120_1 - Piezosystem Jena. 1 channel controller with USB
  • PrecisExcite - LED illuminator (usable as a shutter device)
  • Prior - Prior stages, shutters, and filter wheels
  • PriorNano - Prior/Queensgate nanopositioning stages
  • RAMPS - RepRap RAMPS board as a stage controller
  • Scientifica - Scientifica stages
  • ScopeLED - DiCon LED-powered brightfield and fluorescence microscopy illuminators, implemented as shutters.
  • SigmaKoki - Sigma Koki stages and shutters
  • SmarActHCU-3D - HCU and CU SmarAct controllers adapter (XY and Z)
  • SouthPort_MicroZ - SouthPort MicroZ stage controller
  • Standa - Standa Microstep Driver
  • StandaStage - Standa Microstep Driver
  • Standa8SMC4 - Standa Microstep Driver (using XIMC interface)
  • SutterLambda - Sutter Shutters, filter wheels, light sources, etc..
  • SutterLambda2 - Sutter Lambda 10-3 controller, shutters, filter wheels, and VF5 tunable filter
  • SutterStage - Sutter XY Stage
  • Thorlabs - Thorlabs XY Stage (brushless DC motor), Piezo Z Stage and Integrated Filter Wheel
  • ThorlabsAPTStage - Thorlabs APT family linear stages
  • ThorlabsDCStage - Thorlabs Linear Stages using the TDC001 Controller (see also: ThorlabsAPTStage)
  • ThorlabsDCxxxx - Thorlabs LED controllers
  • ThorlabsElliptecSlider - Thorlabs Elliptec sliders ELL6, ELL9, ELL17 and ELL20.
  • ThorlabsFilterWheel - Thorlabs Filter Wheel
  • ThorlabsMFC1 - Thorlabs MFC1 Motorized Microscope Focus Controller
  • ThorlabsSC10 - Thorlabs shutter controller
  • Tofra - XY and Z stages, filter wheel, motorized filter cube slider, and LED illuminator
  • UserDefinedSerial - Shutters and state devices that can be controlled with simple serial commands
  • Vincent - Vincent Uniblitz controllers
  • WieneckeSinske - WSB PiezoDrive CAN XY stage
  • Xcite - EXFO X-Cite 120 PC Fluorescent Lamp / Shutter
  • XCite120PC_Exacte - Lumen Dynamics X-Cite 120PC and exacte adapter
  • XCiteLed - LED controller
  • XCiteXT600 - X-Cite TURBO and XT600 series
  • Zaber - Zaber linear and XY stages, filter wheels

Communication ports, TTLs, DAQs, etc.

  • Arduino - Open Source Programmable Digital/Analogue IO board
  • Arduino32bitBoards - 32bit Open Source Programmable Digital/Analogue IO boards
  • CustomArduino - Arduino-based devices matching existing device adapters
  • DTOpenLayer - DT OpenLayer Digital IO boards
  • ESIOImagingControllers - Microcontrollers for hardware triggering and synchronization
  • FreeSerialPort - Communicate directly through a serial port
  • ITC18 - controls shutters, cameras, pifocs, anything that can use either a TTL signal or a ±10 V signal
  • K8055 - Velleman Digital IO board (all platforms)
  • K8061 - Velleman Digital IO board (all platforms)
  • MCCDAQ - Measurement Computing PCI-DDA08/16
  • National Instruments - See NI100X and NIMultiAnalog
  • NicoLase An open-source diode laser combiner, fiber launch, and sequencing controller for fluorescence microscopy
  • NI100X - NI I/O boards - DAQmx interface
  • NIMultiAnalog - NI boards with multiple analog outputs
  • SerialManager - Serial Ports on Windows
  • SerialManagerUnix - Serial Ports on Mac and Linux
  • TriggerScope - TriggerScope digital and analog controller
  • TriggerScopeMM - TriggerScope v3 with Micro-Manager firmware
  • ParallelPort - TTLs on parallel port (Windows only)
  • USBManager - Micro-Manager internal USB communications driver

Light sources

  • AgilentLaserCombiner - Agilent MLC
  • AndorLaserCombiner - Andor laser launch
  • BlueboxOptics_niji - Bluebox Optics niji 7 channel LED light source
  • CoboltOfficial - Cobolt lasers 06-01 Series, Cobolt Skyra
  • Cobolt - Cobolt laser controller
  • CoherentCube - Coherent CUBE laser controller
  • CoherentOBIS - Coherent OBIS laser controller (Single Laser Remote)
  • Coherent Scientific Remote - Coherent OBIS laser controller (Scientific Remote and Single Laser Remote)
  • LaserQuantumLaser - gem/ventus/opus/axiom series from LaserQuantum
  • Lumencor Light Engine - All Lumencor Light Engine models
  • LumencorSpectra - Solid state illuminator from Lumencor
  • Mightex - LED driver/controllers
  • Mightex_BLS - BLS Control Modules
  • MightexPolygon - Mightex Polygon multiwavelength patterned illuminators
  • Omicron - Omicron Laser Controller
  • Oxxius - Oxxius Laser Controller
  • Oxxius_combiner - Oxxius combiner; hub for multiple laser sources
  • PolychromeV - Illumination system from Till Photonics
  • Prairie Aurora Laser Launch - Prairie Aurora Laser Launch Interfacing using a Velleman K8061
  • Sapphire - Lasers from Coherent
  • Skyra - Skyra laser controller
  • Stradus - Vortran Stradus laser driver
  • Toptica_iBeamSmartCW - Toptica iBeamSmart laser series
  • Toptica_iChrome_MLE - Toptica iChrome Multi Laser Engine
  • Toptica_iChrome_MLE_TCP - Toptica iChrome Multi Laser Engine over TCP link
  • USB_Viper_QPL - Excelitas/Qioptiq iFLEX-Viper Laser Engine
  • Versalase - Vortran Versalase laser driver
  • YodnLighting - YODN Lighting lamp device adapter for E600 serial products

Other devices

  • AAAOTF - AOTF controller from AA Optoelectronics
  • Aladdin - Syring pump controller from Aladdin
  • AndorShamrock - Andor Shamrock Spectrographs
  • Aquinas - Aquinas Microfluidics Controller
  • AOTF - NEOS AOTF control through parallel port. Can be used for any TTL-controllable shutter
  • ASIwptr - ASI well-plate transfer robot
  • CARVII - BD/CrEST CARV II spinning disk confocal
  • Diskovery - Spectral/Andor spinning disk confocal/TIRF module
  • DLP4000 - Digital Mirror Device
  • GenericSLM - Any spatial light modulator that can be controlled via computer video output port.
  • ImageProcessorChain - Virtual device driver for processing images in C++
  • LumencorCIA - Camera synchronization for the Lumencor Spectra
  • MaestroServo - Pololu Maestro Servo controller
  • MicroPoint - Galvo-based phototargeting device from Andor
  • Mosaic3 - Andor Mosaic DMD Projection Device
  • Okolab - Okolab Microscope Incubators and Gas Controllers
  • OVP_ECS2 - Optic Valley Photonics ECS-2 environmental controller
  • Pecon - Pecon Incubation System
  • PeCon2000 - PeCon 2000 Incubation Controllers (USB-connected)
  • pgFocus - Open Software/Hardware Focus Stabilization from BIG
  • Rapp - Rapp UGA40 photobleaching/photoactivation unit
  • SimpleAutofocus - Image-based autofocus software 'device'.
  • SpectralLMM5 - Spectral laser line controller
  • SutterMPC - Multi manipulator controller
  • Utilities - Virtual devices providing extra functionality to Micro-Manager
  • VariLC - Tunable liquid crystal polarization modulators from CRi
  • VisiTech_iSIM - VisiTech iSIM
  • Yokogawa - Yokogawa CSU22
  • Yokogawa CSUW1 - Yokogawa CSUW1
  • Yokogawa CSUX - Yokogawa CSUX
  • XLight - CrestOptics X-Light spinning disc confocal system
  • The HSi-300 Hyperspectral Imager can be controlled with Micro-Manager (not yet included in the distribution, contact Gouch & Housego for details)
Retrieved from 'https://micro-manager.org/w/index.php?title=Device_Support&oldid=11823'

The SpectraPro® HRS ensures high spectral resolution, as well as an astigmatism-corrected design for multichannel fiber applications. With dual exit ports the SpectraPro HRS can be used as two array detectors or as both a monochromator and spectrograph.

  • 60% improvement in spectral resolution and SNR
  • Astigmatism-corrected optical system
  • Interchangeable grating turrets
  • Calibrated with IntelliCal system
  • Optimised for multi-detector operation

Key Features

New ResXtreme Spectral Deconvolution Technology

ResXtreme improves spectral resolution and peak intensity of spectral lines by up to 60%, with an overall improvement in spectral uniformity of 60% at all CCD positions.

Princeton Usb Devices Driver Adapter

Significantly improving signal-to-noise, ResXtreme is included as standard with all SpectraPro HRS systems, ensuring optimal spectral results.

Full-size Dual Focal Planes

Devices

The SpectraPro HRS has two ports for the mounting and operation of two cameras, enabling operation as both a monochromator and a spectrograph.

AccuDrive™

AccuDrive™ software is able to automatically identify the turret and gratings installed on start-up performing several optical alignment routines to ensure accurate initialization.

This allows for an improvement in wavelength accuracy and repeatability, outperforming typical scanning systems in accuracy and reproducibility.

Customizable Experimental Set-up

The SpectraPro HRS can be tailored for increased wavelengths (rectangular format sensors) and spectral imaging applications (square format sensors). Both front-and back-illuminated devices, as well as deep depletion devices, allow for multiple experimental set-ups.

The SpectraPro HRS is also compatible with numerous accessories such as light sources, single-channel detectors, fiber optics bundles and filter wheels.

Install Usb Driver

Interchangeable Triple Grating Turrets

The SpectraPro HRS is able to optimize systems for wavelength coverage, optical throughput, and spectral resolution via three grating turrets. These turrets feature kinematic mounts and self-align to the optical system when installed.

Exclusive High-Performance Optical Coatings

Taking advantage of the Acton #1900 enhanced aluminium optical coating, the SpectraPro HRS has highest reflectivity from UV-IR providing maximum optical system throughput.

The protected silver option provides ≥98% average reflectivity from NIR to 400 nm.

IntelliCal Wavelength Calibration System

With 10x greater wavelength accuracy, the IntelliCal wavelength calibration system uses dual mercury and neon-argon light sources to calibrate wavelengths within the UV-IR range.

The intensity calibration corrects relative intensity of spectra data and removes hardware includes and etaloning effects.

Powered by LightField Software

Powerful and intuitive software with built-in math engine allows for the complete control of cameras and spectrographs, with real-time image analysis and spectral data.

LightField software provides seamless integration of hardware controls and direct data acquisition into programmes such as National Instruments’ LabVIEW® and MathWorks’ MATLAB®. This software also fully supports IntelliCal automated wavelength and intensity calibration.

Family Specifications

Focal plane size14 mm x 30 mm
Scan range0-1500 nm
Grating size68 x 68 mm standard
68 x 84 mm optional
Supported interfacesUSB 2.0

Spectrometer Models

Focal Length
CCD Resolution**
Datasheet
Focal Length
Aperture Ratio
CCD Resolution**
Linear Dispersion*
Datasheet
Focal Length
CCD Resolution**
Datasheet
Focal Length
Aperture Ratio
CCD Resolution**
Linear Dispersion*
Datasheet
Focal Length
CCD Resolution**
Datasheet
Focal Length
Aperture Ratio
CCD Resolution**
Linear Dispersion*
Datasheet
Focal Length
CCD Resolution**
Datasheet
Focal Length
Aperture Ratio
CCD Resolution**
Linear Dispersion*
Datasheet

* with 1200 g/mm grating at 435.8 nm and 10 micron slit width at 4 mm slight height
** with ResXtreme and 1200 g/mm grating at 435.8 nm 20 micron pizel, 20 micron slit width